Wet separation of weakly magnetic metal ores such as hematite, limonite, siderite, manganese ore, ilmenite, and wolframite is a difficult step in mineral processing. Ordinary magnetic separators work mainly on ferromagnetic minerals. They are less effective for weakly magnetic and non-magnetic minerals. The electromagnetic separator combined with a high intensity magnetic separator design addresses this problem. It integrates electromagnetic excitation with a high-gradient magnetic matrix. Hengci Magnetic has extensive experience in magnetic circuit design and on-site commissioning for this equipment. This article explains magnetic field strength and adjustment, fine particle capture, pulsation, cooling, a field case, installation, operation, and safety.

How the Electromagnetic Separator and High Intensity Magnetic Separator Work Together
Adjustable Magnetic Field for Different Ore Types
Customers often ask whether the magnetic field is strong enough and whether it can be adjusted. The electromagnetic separator uses a unique magnetic circuit. It generates a magnetic field above 1 Tesla in the separation zone. The field is uniformly distributed, with no magnetic flux leakage points. The coil uses fully sealed oil cooling with external circulation. The winding coil generates a magnetic field through the upper and lower magnetic yokes. Excitation voltage is supplied by a three-phase silicon-controlled rectifier. This makes magnetic field adjustment convenient. Different minerals can use different excitation settings on the same high intensity magnetic separator.
Matching Field Strength to Weakly Magnetic Minerals
Weakly magnetic limonite and siderite need a stronger magnetic field. Slightly more magnetic ilmenite and wolframite can use lower excitation. This avoids carrying non-magnetic particles into the concentrate. The electromagnetic separator therefore provides flexible field control. The high intensity magnetic separator can be tuned to the ore. This matching process is essential for efficient recovery.
Fine Particle Capture in the High Intensity Magnetic Separator
High Gradient Magnetic Matrix
Fine particle capture depends on the magnetic gradient at the matrix surface. During separation, the rotating ring turns in a set direction. Slurry enters the feed hopper through the feed pipe and flows through the ring along the upper gap of the magnetic system. The induction matrix is made of high-permeability stainless steel rods. It is magnetized in the background magnetic field. A very high gradient magnetic field forms on the matrix surface. Magnetic particles in the slurry are attracted to the matrix surface. They are carried by the rotating ring to the top non-magnetic zone. Flushing water washes the magnetic material into the concentrate hopper. Non-magnetic particles flow along the lower gap into the tailings hopper. This is how the high intensity magnetic separator captures fine weakly magnetic particles.
Pulsation to Reduce Mechanical Entrainment
Mechanical entrainment and matrix clogging are common customer concerns. The electromagnetic separator includes a pulsation mechanism. Pulsation speed can be precisely adjusted by a variable frequency drive. When the diaphragm reciprocates under the pulsation stroke box, the slurry level must cover the lower matrix of the ring. The slurry in the separation chamber moves up and down. The pulsating fluid force keeps the ore particle group in a loose state. This effectively eliminates mechanical entrainment of non-magnetic particles and improves magnetic concentrate grade. Slurry pulsation also helps prevent matrix clogging. The high intensity magnetic separator therefore delivers cleaner concentrate and more stable operation.
Cooling and Protection for Continuous Operation
Fully Sealed Oil Cooling
Long-term coil heating affects continuous operation. The electromagnetic separator uses fully sealed oil cooling with external circulation. The internal coil is completely immersed in transformer oil. The coil uses a laminar interval distribution. A dedicated transformer oil pump circulates the oil. Heat is dissipated through a condenser with forced air cooling by axial fans. This gives low temperature rise, slow coil aging, long service life, and no pollution. It replaces water cooling. If the cooling oil temperature is too high or the excitation circuit is shorted, the rectifier protection device automatically cuts off the excitation power and alarms. When an alarm occurs, check the cooling oil temperature or excitation circuit. After troubleshooting, press the reset key and re-excite. These features make the high intensity magnetic separator reliable for continuous duty.
Protection System for the Electromagnetic Separator
The electromagnetic separator includes protection against overheating and excitation circuit faults. The rectifier protection device improves safety. Operators should follow the alarm procedure. Check oil temperature and excitation circuit. Reset only after the fault is cleared. This prevents damage to the coil and maintains stable separation.
Case Study: Electromagnetic High Intensity Magnetic Separator in Iron Ore Processing
Improving Concentrate Grade and Reducing Tailings Loss
An iron ore concentrator processed finely disseminated red ore below 1.3 mm. The previous ordinary magnetic separator lost weakly magnetic particles to tailings. Concentrate grade fluctuated, and operators had to adjust water and slurry frequently. Hengci Magnetic supplied an electromagnetic high intensity magnetic separator for this duty. The excitation current was set to a suitable level according to the ore sample. A higher magnetic field was combined with pulsation strokes. Slurry entered the ring through the feed hopper. Magnetic particles were captured by the matrix and carried to the top non-magnetic zone. Flushing water washed them into the concentrate hopper. After commissioning, magnetic concentrate grade became more stable. Weakly magnetic iron loss in tailings decreased. The frequency of water and slurry adjustment dropped. This case demonstrates the value of the electromagnetic separator and high intensity magnetic separator in real production.

Installation, Operation, and Safety
Installation and Startup Sequence
The anchor bolts of the electromagnetic separator should be on the same horizontal plane. Tighten or weld the anchor bolts. Do not leave them loose. Prevent iron chips or impurities from entering the equipment during installation. Before trial operation, move the feed pipe outlet outside. Confirm that coarse particles in the pipe have been flushed out. Then move it back. After installation, run the machine without load. Follow the startup sequence: start the oil pump, confirm no oil leakage, start the cooling fan, start the ring, start pulsation, and start excitation. This sequence protects the high intensity magnetic separator.
Operating Rules and Matrix Maintenance
Do not stop the ring while it is loaded with ore. This can cause matrix clogging. In general, do not stop the ring under load. Check the matrix box compression bolts once per shift. Damaged stainless steel compression bolts must not be replaced with ordinary bolts. These rules keep the electromagnetic separator reliable.
Magnetic Field Safety
The high intensity magnetic separator generates a very strong magnetic field. The field is concentrated in the excitation coil and ring, with some weak field around the equipment. The magnetic field can seriously damage heart pacemakers. People with pacemakers should approach only after the magnetic field is completely off. Do not use ferrous tools or objects near the magnetic field, especially sharp objects. Do not bring computer disks, tapes, credit cards, or other magnetic storage devices near the equipment. These precautions prevent injury and data loss.
Conclusion: Choose the Right Electromagnetic High Intensity Magnetic Separator
Selecting an electromagnetic separator and high intensity magnetic separator means matching mineral type, feed particle size, slurry density, iron content, and expected excitation conditions. Provide these details to Hengci Magnetic. We will configure the magnetic circuit, matrix specification, and pulsation parameters. With the right electromagnetic high intensity magnetic separator, weakly magnetic ore recovery improves, concentrate grade stabilizes, and tailings loss decreases.
Categories